Quality Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain factory
<
Quality Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain factory
Quality Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain factory
Quality Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain factory
Quality Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain factory
Quality Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain factory
Quality Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain factory
>

Jet Dancing Fountains Four Hue Gradient Zone Control Floating Musical Fountain

Product Summary

Jet Dancing Fountain Four Hue Gradient Zone Control Night Show A dancing fountain built as a mass, not a line: jets stepped in height to make a crown, fan plumes widening the base, four colors held side by side with no seam where they meet. A Bank Of Jets, Not A Row The centre is a packed bank of ...

Product Custom Attributes

Powersupply:
220V/110V AC
Maintenance:
Easy Maintenance With Modular Components
Product Name:
Dancing Fountain
Applications:
Public Parks, Shopping Malls, Hotels, Entertainment Venues
Material:
Stainless Steel And LED Components
Controlsystem:
PLC Programmable Controller
Lighting:
Multicolor LED Lights
Music Synchronization:
Yes, Supports Music And Light Synchronization
Highlight:

jet dancing fountains

,

dancing fountains four hue

,

jet floating musical fountain

Basic Properties

Place of Origin:
China
Brand Name:
DEWY
Certification:
CE, RoHS
Model Number:
Dancing - 16

Trading Properties

Minimum Order Quantity:
1 Set
Price:
USD 42200-63219
Packaging Details:
Fixed transport of plywood wooden boxes
Delivery Time:
About 7-30 work days
Payment Terms:
L/C,D/A,D/P,T/T
Supply Ability:
1 set in 30 work days

Product Description

Jet Dancing Fountain Four Hue Gradient Zone Control Night Show

A dancing fountain built as a mass, not a line: jets stepped in height to make a crown, fan plumes widening the base, four colors held side by side with no seam where they meet.

A Bank Of Jets, Not A Row

The centre is a packed bank of vertical jets, tallest in the middle, dropping a step at each edge until the silhouette reads as a crown. Spacing is tight enough that from the far pavement the bank looks like one body of water.

Four Hues In One Basin

Four colors at once need four zones and enough nozzles per metre to hide the join. Below about six nozzles in a group the eye finds the seam; above it the change reads as a gradient that runs along the bank rather than as blocks.

Why The Top Of A Tall Jet Turns To Mist

A jet does not simply fall back. Air moving past the column shears it, and past a certain height the surface breaks into droplets fine enough to travel with the wind. That is why tall jets need a bigger nozzle and a stilling chamber: coarse water holds its shape higher, and the crown stays a crown instead of a cloud.

Fans That Widen The Base

Fan plumes sit at both ends and throw the composition outward, so the basin looks wider than its plan. Their reach is set against the coping, and in a crosswind they are the first thing trimmed, since a fan loses shape long before a vertical bank does.

Cues That Hold Their Place

A gradient is stored as offsets, not as four separate looks: shift one number and the whole sweep moves. Weekly schedules call the same file, so an operator can change the hour without touching the color.

 

Show Notes

Q: How many color zones do four hues need?
A: Four, one per hue, plus a spare if you want a warm wash on the fans. Zones are cut on the manifold, so adding one later means new pipework.

Q: How long does commissioning take on site?
A: Two to three days for a basin this size: level check, zone test, then the first file run at dusk with the client watching.

Q: What happens if the control panel fails?
A: The show keeps a fixed fallback palette, and we hold spare driver cards for the model supplied. A replacement card is a swap, not a rewire.

Q: Can the gradient run the other way?
A: Yes. Direction is a sign in the file, so a left to right sweep becomes right to left without new hardware.

Q: How is a basin show like this priced?
A: Nozzle count, bank height, zones and files. Send the basin plan and the height you want, and the quote follows that layout, then deposit, wet test video, balance, crates in fixed transport of plywood wooden boxes.

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.